Technical Parameters
| project | parameter |
| Measuring range | 200Pa~60MPa |
| Ambient temperature | -40℃~+85℃ |
| Medium temperature | -40℃~±120℃ |
| stability | 0.15% URL/15 years |
| Output | 4~20mA HART |
| weight | 1.6kg |
| full range | 6kPa | 40kPa | 250kPa | 3MPa |
| Overload pressure | 7MPa | 7MPa | 4MPa | 15MPa |
| full range | 10MPa | 21MPa | 40MPa | 60MPa |
| Overload pressure | 20MPa | 60MPa | 60MPa | 70MPa |
| Accuracy | |
| A | Basic error ±0.05% (not applicable to range B and R) |
| B | Basic error ±0.075% |
| C | Basic error ±0.1% |
| Range | |
| Gauge pressure RP1002 | |
| B | 0-0.6kPa~6kPa |
| C | 0-2kPa~40kPa |
| D | 0-2.5kPa~250kPa |
| F | 0-30kPa~3MPa |
| G | 0-0.1MPa~10MPa |
| H | 0-0.21MPa~21MPa |
| I | 0-0.4MPa~40MPa/(0-4~400bar) |
| R | 0-0.6kPa~6kPa [overload protection to 7MPa] |
| S | 0-2kPa~40kPA [overload protection to 7MPa] |
| Absolute pressure RP1003 | |
| L | 0-2kPa~40kPa |
| M | 0-2.5kPa~250kPa |
| O | 0-30kPa~3MPa |
| T | 0-2kPa~40kPa [overload protection to 7MPa] |
The central sensing unit uses high-precision silicon technology, accurate to +0.05% (up to +0.025%)
Overload protection diaphragm design
·Good anti-overload performance for small range gauge pressure/absolute pressure transmitter
Temperature performance can reach ±0.04%/10, and the temperature effect is small
· Up to 100:1 range adjustment, wider adaptability
EMC complies with GB/T 18268.1-2010